Permit No. BLD2017-1494 Permit Type   SINGLE FAMILY Site Address   4309 LORION DR.
ROCKWALL, TX 75087
Applied   05/17/2017 Applicant   Drees Custom Homes
Approved   05/17/2017 Owner   Drees Custom Homes
Issued   07/18/2017 Contractor   Drees Custom Homes
Parent Permit No.   Description   NEW SINGLE FAMILY
  Notes   CONSTRUCTION CODES – 2015 International Residential Code & 2014 NEC Code and local amendments. 80% masonry construction. 2015 IRC narrow wall bracing requirements must be meet. Must use traffic rated cans in traffic areas. 4-3” Trees Required For inspection www.rockwall.com/buildinginspections/inpectionreq.asp.
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/19/2017P1-T-POLEJames HopphanAPPROVED

 08/09/2017P3-FOUNDATIONJohn AnkrumAPPROVED

 07/28/2017P2-PLUMB ROUGHJames HopphanDISAPPROVENot ready.

 07/31/2017P2-PLUMB ROUGHJames HopphanAPPROVED

 08/07/2017P3-FOUNDATIONJames HopphanDISAPPROVE(8/7/2017 11:16 AM JH) FD06 - Beams have cave-ins and loose dirt - R403.1, too much loose dirt in the beams. check all beams.

 08/08/2017P3-FOUNDATIONJames HopphanDISAPPROVE1. Same as prior inspection. Loose dirt thru out the beams.

 10/11/2017FLAT WORKJames HopphanDISAPPROVENot ready, trade still woring , rebar on grade.

 11/14/2017P5-TEMP UTILITIESJames HopphanAPPROVEDok to release gas serv.(11/14/2017 4:56 PM DG1) ATMOS 9006956472

 09/11/2017P4-FRAMINGMichael TiehenDISAPPROVE W/PENALTY1) Missing cap on hvac flue. 2) Missing joist hangers at front porch and in kitchen. 3) Water heater flue pipe must have min. 1" clearance to sheetrock, framing and roof deck. 4) Studs at fireplace chase are over spaced. (24" O.C. min.) 5) Provide proper size hanger for triple 2X8s in single car garage. 6) Fire block stud spaces to attic at exterior wall in single car garage. 7) Properly draft stop 2nd floor duct chase to attic. 8) Relocate or protect a/c lines at roof deck 2nd floor.

 09/13/2017P4-FRAMINGMichael TiehenAPPROVED

 10/12/2017FLAT WORKMichael TiehenAPPROVED